Review and Buy Wirless Alarm System Life SOS LS Base Unit at the best price and offers in Dubai – UAE at Shop Security & Surveillance Systems. LS BASE UNIT LIFE SOS ALARM By adopting modern microprocessor control and communication technologies, the LS is designed to provide all the. View and Download LifeSOS LS operation manual online. They represent the system operation mode and alarm/ warning status as listed in the following.

Author: Tygokus Dataxe
Country: Ecuador
Language: English (Spanish)
Genre: Video
Published (Last): 11 September 2009
Pages: 478
PDF File Size: 18.81 Mb
ePub File Size: 20.98 Mb
ISBN: 890-8-71708-527-1
Downloads: 14075
Price: Free* [*Free Regsitration Required]
Uploader: Kazinris

The comply with the FCC RF exposure compliance requirements, this device and its antenna must not be co-located or operating to conjunction with any other antenna or transmitter.

life sos alarm

The LS is not only a security system but also a home automation controller that allows you to set as many as 16 programmable switches to execute daily commands throughout a whole week. Battery pack 1 is 9.

Plug in the power adaptor. Place the Base Unit in the central area at your home or business. Keep the Base Unit away from large appliances and other metal objects. Duress Code User X switch control X switch control module is an optional device. Close or open the alarm relay terminals on the rear panel. The Base Unit can store event records in its memory. These events can be checked by time sequence or by entering the date information.

Use the keys to move up and down the screen.

Wirless Alarm System Life SOS LS Base Unit | Souq – UAE

Refer to Installer Mode Exit Delay. User 9 and User 10 are also called Latchkey Users. When you leave your home or business, set the system into Away Mode. When you pick up the phone, your voice on the line will trigger the appropriate message from the LS If you connect a fax machine or auto-answering machine on the same telephone line, you might need to refer to their manuals and Appendix A-7 to avoid any disoperation.

  BATAS PAMBANSA 881 PDF

The Installer Mode is for the installer to set up the system. If the Base Unit does not receive the RF check signal from a certain sensor within the Sensor Supervise time, the LS will consider this sensor to be missing and issue a warning message.

Permanent OFF The LS can check the telephone line voltage and alatm the line is cut, the siren will go off the Inner Siren should be switched on to alert the user.

Never check the telephone line state. These will be dialed only when the LS is triggered aalarm the specified alarm. For example, the fire number will be dialed only in a fire alarm.

LIFESOS LS OPERATION MANUAL Pdf Download.

Latchkey number Power status report number: This number has two purposes: Each pause is equivalent to a 3-second break. With no acknowledgement, the call will be deemed to have failed and will be redialed in the next loop.

After an alarm call connects successfully, the LS will play the prerecorded voice message that corresponds to the alarm type.

The messages should be recorded in their specified segments. Latchkey Away 4 seconds: The voice to be played when a latchkey user sets the system in AWAY mode. The Base Unit will generate beeps during the Entry Delay interval and the beeping speed will get faster until the end of the delay time. The LS uses smart code technology. Each sensor has a unique ID that is preset at the factory. For all devices Device On Duty: This sensor is working in the system currently.

The Relay will not act and sirens will keep silent when there is an alarm issued by this device. For Burglar allarm Bell ON: In Disarm Mode, doorbell chime will not sound when receiving a trigger signal Tamper Siren In Disarm On: Tamper Siren In Disarm Off: The siren will not go off when receiving the tamper signal from sensors or from the Base Unit in Disarm Mode.

  IRCON MIRAGE PDF

Set Password Mode Alram Report: Mode Change Report Off: Follows local regulations, other frequencies as requested Frequency: The output voltage depends on the power adaptor and will be shut down if the external power fails.

These two terminals are the Alarm Relay Outputs. Also See for LS Operation manual – 41 pages. Page of 42 Go.

Table of Contents Add to my manuals Add. Initial State X switch control X switch control lifezos is an optional device. Page 17 Exit Delay: Installer Mode The Installer Mode is for the installer to set up the system. Page 24 Sensor Supervise Time: Page 26 Permanent OFF The LS can check the telephone line voltage and if the line is cut, the siren will go off the Inner Siren should be switched on to alert the user.